Authorized Stockiest and Services



L&T PLASTICS MACHINERY LIMITED
 

 -  Solution for Plastic Injection Moulding, Extrusion and Related Industries  -

   

Home Page   .   Company Profile   .   Contact Us

 

chillers

air cooled chillers

Features
• High Pressure & Low Pressure Trip
• High Voltage Trip & Low Voltage Trip
• Overload Trip for fan, processes pump
• Low Temperature Anti-Freeze Safety Thermostat
• Safety pressure switch for process pump
• Internal Over Load Trip for Compressor
• Glass with moisture indicator
• Single phase & phase reversal preventer, MCB for Fan Motor
• Manual By pass valve
• Energy efficient Shell & Tube with immersion type Evaporator
Indications
• Pump , Compressor, Condenser ON/OFF
• Programmable digital controller
• Common Light indication with Alarm

Refrigerants circuit add ons
• Accumulator
• Liquid receiver
• High/Low pressure Gauges
• Filter dryer
• Slight Glass with Moisture Indicator
Method of Cooling
Water flows through Shell and Tube with immersion type evaporator and maintains water at required temperature inside the inbuilt SS tank. Separate process Pump will circuit water to the process and returned to the tank. Process pump, Internal circulation pump, Heat Exchanger etc… are housed in the chiller and controled by PLC.

- - - - - - - - - - - - - - - - - - - - - - - -

 

WATER COOLED CHILLERS

 

Features
• High Pressure & Low Pressure Trip
• High Voltage Trip & Low Voltage Trip
• Overload Trip for fan, processes pump
• Low Temperature Anti-Freeze Safety Thermostat
• Safety pressure switch for process pump
• Internal Over Load Trip for Compressor
• Glass with moisture indicator
• Single phase & phase reversal preventer, MCB for Fan Motor
• Manual By pass valve
• Energy efficient Shell & Tube with immersion type Evaporator
Indications
• Pump , Compressor, Condenser ON/OFF
• Programmable digital controller
• Common Light indication with Alarm

Refrigerants circuit add ons
• Accumulator
• Liquid receiver
• High/Low pressure Gauges
• Filter dryer
• Slight Glass with Moisture Indicator
Method of Cooling
Internal circulation pump will circuit water through Shell and Tube Condensor and maintains water at required temperature inside the inbuilt SS tank. Separate process Pump will circuit water to the process and returned to the tank. Process pump, Internal circulation pump, Heat Exchanger etc… are housed in the chiller and controlled by PLC.

 


   Contact : Telefax : +912027654414,  Cell : +919371160187
   

 email :
chandane@narendraindia.com, chandane@vsnl.com

 

Copyright © 2009 narendraindia.com. All rights reserved. Privacy Policy. Website best viewed in 1024*768 Resolution